0515-0001. 10 x 1.5 mL. Please sign in to view pricing. EA. View Details. Showing products 1 to 32 out of 32. Sort by: ACCURUN® Molecular Diagnostics and reference materials monitor molecular assay performance and provide confidence in PCR test results. Clinical laboratories trust SeraCare to ensure they have a robust quality control program.

Accuplex. Things To Know About Accuplex.

AccuPlex virus products are non-replicative recombinant viruses that are intended to assess the performance of the full process of a molecular test. AccuPlex ...AccuPlex™ Reference Material Kits are designed to measure day-to-day performance of the assay, providing both a positive and a negative reference solution. Product Description. Material Numbers. Pack Size. Concentration. AccuPlex SARS-CoV-2, Flu A/B and RSV Molecular Controls Kit*. 0505-0260. Positive.To understand critical micelle concentration, or CMC for short, we need first to understand surfactants. Surfactants are amphiphilic molecules that have hydrophilic and hydrophobic parts (figure 1A).If you need to set us up as a new vendor, please reference our W-9. AccuPlex™ Flu A/B and RSV Reference Material Kit is formulated for use with multiplex test methods that can detect influenza A/B and respiratory syncytial virus. Included are positive reference material directed against Flu A/B and RSV, as well as negative reference material ... ACCURUN 325 Series 700 is manufactured from human serum or plasma, reactive for HBV DNA and non-reactive for antibodies to HIV 1, HIV 2, HCV and HTLV. ACCURUN 325 can help you avoid costly repeats and, more importantly, false negative or positive results by allowing you to monitor your HBV DNA assay with a reliable source of positive material.

SeraCare offers an expansive portfolio of disease state samples, characterized extensively on current FDA, CE-marked, and RUO methods and platforms to provide you with a detailed reactivity profile to advance your research or validation applications. Raw plasma, serum, and other matrices collected from donors worldwide provides you with a ...... of SNAP ® 4Dx ® Plus and AccuPlex ® 4 for the Detection of Antibodies to Borrelia burgdorferi and Anaplasma phagocytophilum"

First PCR test for parasites detects 20 intestinal parasites, emerging threats like treatment-resistant hookworm and zoonotic Giardia. Orlando, FL— NAVC Veterinary Meeting and Expo (VMX) booth #4222 —January 17, 2022—Representing two decades of foundational research and a new standard of care in veterinary medicine, Antech Diagnostics announced today veterinary medicine’s most ...

May 7, 2020 · SeraCare AccuPlex SARS-CoV-2 Reference Material Kit 7.5 μl sample in 10 ng UHR background NC_045512 Twist Synthetic SARS-CoV-2 RNA Control 1 Titration of viral copies into 10 ng human saliva RNA background MT007544.1 a. The recommended minimum RNA input for reverse transcription is 10 ng. For best AccuSpan linearity panels are designed to span the dynamic range of quantitative infectious disease assays and evaluate instrumentation analytical sensitivity. Linearity panels effectively challenge assay performance at defined intervals to ensure consistency throughout the entire reportable range. In addition to linearity studies, these panels ... Apr 6, 2021 · VCA Accuplex® Pilot Heartworm • Lyme • Ehrlichia • Anaplasma The updated Accuplex test Thank you for participating in the VCA Accuplex Pilot Program. Your clinical investigation and feedback is invaluable to Antech’s ability to provide unparalleled accuracy with results reported and innovation in veterinary diagnostics. SeraCare offers best-in-class Quality Control Tools for NGS clinical laboratories and IVD assay development. Develop, validate, and Monitor your assays with confidence. Custom reference materials, controls, and reagents for NGS, molecular and serology, biological materials, and reagents.

Add: No.318, Bailong Industry Park,Minhou, Fuzhou, Fujian, China. Tel: 0086-591-8399 3333. Fax: 0086-591-8336 1000. Feedback Email: [email protected]

AccuPlex recombinant closely resembles the wild-type mammalian pathogenic virus. This enables the release of the viral genome at a similar rate to the wild-type virus during the nucleic acid sample preparation process. AccuPlex recombinant material mimics a real patient sample in your workflow, serving as a full-process control for your assay.

The AccuPlex SARS-CoV-2 Reference Material contains recombinant virus that is heat-treated and replication-defective. However, the reference material should be handled as infectious materials using standard precautions and in accordance with Good Laboratory Practices to avoidFor this, tenfold serial dilutions containing between 100 and 10,000 genome copies of SARS-CoV-2 per ml (AccuPlex SARS-CoV-2 Verification Panel – Full Genome, Seracare Life Sciences, Inc., catalog number 0505-0168) were prepared in VTM and tested in triplicate and in three independent runs. Data analysisSeraCare’s AccuPlex recombinant material serves as a true molecular process control for your diagnostic assays. Compatible with multiplexed RT-PCR and NGS-based assays, AccuPlex custom recombinant materials are constructed with a replication-deficient mammalian virus, producing a safe, non-infectious material (Figure 1).SeraCare’s AccuPlex recombinant material serves as a true molecular process control for your diagnostic assays. Compatible with multiplexed RT-PCR and NGS-based assays, AccuPlex custom recombinant materials are constructed with a replication-deficient mammalian virus, producing a safe, non-infectious material (Figure 1). 21 cze 2016 ... Utilizing AccuPlex recombinant virus technology, SeraCare's Zika reference material contains the entire RNA genome of the ZIKV 2007 strain ...procedures. AccuPlex controls contain non-replicative recombinant viruses that are intended to assess the performance of the full process of a molecular test. AccuPlex can be used to evaluate test proficiency and accuracy through the full process because they are encapsulated viruses which require extraction and amplification.

*The CDC-manufactured Influenza SARS-CoV-2 (Flu SC2) Multiplex Assay is designed for use at CDC-supported public health laboratories and will not replace any SARS-CoV-2 diagnostic tests currently used in commercial laboratories, hospitals, clinics, and other healthcare settings.specimens. AccuPlex SARS-CoV-2 reference material must go through an extraction process prior to detection by PCR. Process the product according to the instructions for unknown samples provided by the test kit or the laboratory’s standard operating procedures. AccuPlex reference materials must NOT be substituted for the positive andACCURUN 325 Series 700 is manufactured from human serum or plasma, reactive for HBV DNA and non-reactive for antibodies to HIV 1, HIV 2, HCV and HTLV. ACCURUN 325 can help you avoid costly repeats and, more importantly, false negative or positive results by allowing you to monitor your HBV DNA assay with a reliable source of positive material. Simple, rapid and convenient diagnostic tools for use in veterinary, human, and research applications. Accuplex Diagnostics was set up in 2011 to develop diagnostic tests for the detection of acute phase proteins such as Serum Amyloid A (SAA), a family of biomarkers present in all animal species which are strongly linked to inflammation and ...1. Select two operators to repeat the Xpert SARS-CoV-2 test on selected vials of AccuPlex positive reference material and AccuPlex negative reference material. 2. Using pipet provided, Operator #1 add 0.3 mL of AccuPlex positive reference material to cartridge #21. Operator #2 add 0.3 mL of AccuPlex positive to cartridge #22. 3.Interpreting your SDMA results. B elow 15 µg/dL. SDMA is normal. Learn why SDMA matters. 15–19 µg/dL. Take action when SDMA results are mildly elevated (15-19 μg/dL) and perform a complete urinalysis to determine if persistent evidence of kidney disease is found and establish next steps. Use the algorithm. ≥ 20 µg/dL.

SeraCare offers an expansive portfolio of disease state samples, characterized extensively on current FDA, CE-marked, and RUO methods and platforms to provide you with a detailed reactivity profile to advance your research or validation applications. Raw plasma, serum, and other matrices collected from donors worldwide provides you with a ...If you do not currently have an eCommerce account, please email your purchase order to [email protected] or contact us at 1.800.676.1881. AccuPlex™ SARS-CoV-2 Omicron Variant Reference Material Kit contains the full SARS-CoV-2 genomic RNA with a focus on S and N-gene mutations within the Omicron variant of concern (VOC) B.1.1.529.

0515-0001. 10 x 1.5 mL. Please sign in to view pricing. EA. View Details. Showing products 1 to 32 out of 32. Sort by: ACCURUN® Molecular Diagnostics and reference materials monitor molecular assay performance and provide confidence in PCR test results. Clinical laboratories trust SeraCare to ensure they have a robust quality control program. SeraCare’s trusted controls and reference materials provide: Patient-like performance for serology, molecular PCR, and sequencing-based assays. Precise titration and high lot-to-lot consistency with excellent signal-to-noise ratio. A wide range of important viral and bacterial pathogens including HIV, HBV and HCV, C.diff, and CT/NG.AccuPlex Multi-Test Canine Occult Heartworm Multi-Test Dermatopathology Consult Avian & Exotic Histopathology/Cytology Heartworm Multi-Test Equine Histopathology/Cytology O&P Multi-Test O&P Multi-Test with Giardia Radiology Review CADET BRAF/Plus Showing 11–20 of 1389 results Container Slides Component Direct smear that has been air dried ...Explore our diagnostic portfolio. Help stop the spread of respiratory diseases with Cepheid’s portfolio of easy-to-use, on-demand molecular diagnostic tests.NOW AVAILABLE! AccuPlex™ SARS-CoV-2 Omicron Variant Reference Material Kit We are pleased to announce the release of our AccuPlex™ SARS-CoV-2 Variant Panel offering has been expanded to include...Mutations in the SARS-CoV-2 genome could confer resistance to pre-existing antibodies and/or increased transmissibility. The recently emerged Omicron subvariants exhibit a strong tendency for ...ACCURUN 325 Series 700 is manufactured from human serum or plasma, reactive for HBV DNA and non-reactive for antibodies to HIV 1, HIV 2, HCV and HTLV. ACCURUN 325 can help you avoid costly repeats and, more importantly, false negative or positive results by allowing you to monitor your HBV DNA assay with a reliable source of positive material. April 27, 2020. Now that COVID-19 diagnostics are available in most of the United States, media reports are surfacing about false-negative test results and the possibility of reinfection. We break down some of the major challenges of SARS-CoV-2 testing, including issues of test performance and interpretation, to give these reports context.

AccuPlex® SARS-CoV-2 · Material de virus recombinante no replicativo. · Verifica el proceso completo de las pruebas moleculares. · Requiere extracción y ...

AccuPlex SARS-CoV-2 Molecular Controls have been designed for use with in vitro assay procedures for purposes of monitoring assay performance. The control is intended for use with nucleic acid based detection assays only. AccuPlex SARS-CoV-2 Molecular Controls Kit is manufactured from recombinant virus particles in viral transport media.

Jun 6, 2021 · The Accuplex comprehensive parasite testing platform offers gold-standard sensitivity for Heartworm testing and Lyme disease testing that is consistent with the ACVIM Consensus Statement. LGC SeraCare AccuPlex Monkeypox Reference Material Kit, contains positive reference material directed against the published CDC and WHO consensus sequences. In cases where true patient samples are difficult to source or too risky to directly handle, AccuPlex technology provides the ideal solution for assay development and QC requirements.If you do not currently have an eCommerce account, please email your purchase order to [email protected] or contact us at 1.800.676.1881. AccuPlex™ SARS-CoV-2 Variant Panel 2 contains the full SARS-CoV-2 genomic RNA with a focus on S-gene mutations in three prominent variants of concern (VOC): Kappa B.1.617, Delta B.1.617.2, and ...The AccuPlex™ SARS-CoV-2, Flu A/B and RSV Verification Panel is formulated for use with multiplex test methods that can detect SARS-CoV-2, flu A/B and respiratory syncytial virus (RSV). Included are three different concentrations of positive reference material as well as negative reference material directed against the human RNase P gene. SeraCare’s AccuPlex recombinant material serves as a true molecular process control for your diagnostic assays. Compatible with multiplexed RT-PCR and NGS-based assays, AccuPlex custom recombinant materials are constructed with a replication-deficient mammalian virus, producing a safe, non-infectious material (Figure 1).SeraCare offers an expansive portfolio of disease state samples, characterized extensively on current FDA, CE-marked, and RUO methods and platforms to provide you with a detailed reactivity profile to advance your research or validation applications. Raw plasma, serum, and other matrices collected from donors worldwide provides you with a ... 18 mar 2020 ... • AccuPlex™ SARS-CoV-2 Reference Material kit. SeraCare Material Number: 0505-. 0126 (5 x 1.5 mL vials, positive reference material; 5 x 1.5 ...1. Select two operators to repeat the Xpert SARS-CoV-2 test on selected vials of AccuPlex positive reference material and AccuPlex negative reference material. 2. Using pipet provided, Operator #1 add 0.3 mL of AccuPlex positive reference material to cartridge #21. Operator #2 add 0.3 mL of AccuPlex positive to cartridge #22. 3.The recombinant viruses used to produce the AccuPlex SARS-CoV-2, Flu A/B and RSV reference material are replication defective and heat-treated. However, handle AccuPlex products and all human blood products as though they can transmit infectious agents. The product is formulated in viral transport media that consists of Tris-bufferedAccuSpan linearity panels are designed to span the dynamic range of quantitative infectious disease assays and evaluate instrumentation analytical sensitivity. Linearity panels effectively challenge assay performance at defined intervals to ensure consistency throughout the entire reportable range. In addition to linearity studies, these panels ... The recombinant viruses used to produce the AccuPlex SARS-CoV-2, Flu A/B and RSV reference material are replication defective and heat-treated. However, handle AccuPlex products and all human blood products as though they can transmit infectious agents. The product is formulated in viral transport media that consists of Tris-buffered The AccuPlex™ analyte verification panel was first diluted into negative human nasopharyngeal (NP) matrix before RNA extraction or direct specimen amplification, and RNA extractions were performed automated using the KingFisher Flex 96 and MagMAX™ Viral/Pathogen II (MVP II) Nucleic Acid Isolation Kit.

We would like to show you a description here but the site won’t allow us.Sixty-two patients were included, with a median age of 59 (51–68) years, and 38 (61.2%) of them were male. Nineteen patients (30.6%) had some chronic underlying conditions, with the most ...LGC SeraCare’s Flu A/B and RSV AccuPlex solution: Non-infectious and replication deficient, enables safe handling in contrast to viral samples. Fully-extractable with a real viral protein coat; superior to “naked” transcribed RNA. 2 year stability at 2 - 8°C.Complete the form below to download the Accuplex Lyme Algorithm. Better Diagnostics. Better Medicine. Subscribe to our newsletter. Antech USA. 1-800-872-1001Instagram:https://instagram. weather in mcallen radarterraria ice featherosrs wall beasttrader joe's citrus heights The recombinant viruses used to produce the AccuPlex SARS-CoV-2, Flu A/B and RSV reference material are replication defective and heat-treated. However, handle AccuPlex products and all human blood products as though they can transmit infectious agents. The product is formulated in viral transport media that consists of Tris-bufferedSeraCare’s SARS-CoV-2 AccuPlex solution: • Non-infectious and replication deficient, enables safe handling of positive material • Fully-extractable with a real viral protein coat; serves as a full-process control • Compatible with assays targeting CDC and WHO consensus sequences. (Table 1) diagram of 5.7 hemi enginefemale luffy fanfic The IDEXX SNAP 4Dx Plus Test is the most accurate solution available for detecting vector-borne disease 1–3 —now with IDEXX DecisionIQ for added clarity in determining next steps. Store tests at room temperature for up to 6 months for improved workflow. Test annually to help prevent the spread of heartworm disease, Lyme disease ...0515-0001. 10 x 1.5 mL. Please sign in to view pricing. EA. View Details. Showing products 1 to 33 out of 33. Sort by: ACCURUN® Molecular Diagnostics and reference materials monitor molecular assay performance and provide confidence in PCR test results. Clinical laboratories trust SeraCare to ensure they have a robust quality control program. cast of mountain monsters ages AccuPlex™ SARS-CoV-2 Reference Material Kit – Full Genome The first page contains the product view or print does not contain two About this package insert Thank you for your interest in this AccuPlex™ product. This package insert consists of two pages. name, the SeraCare logo, and contact information. The second page contains the complete Accuplex is a canine vector-borne disease screening for heartworm, Lyme disease (includes screening for antibodies against two C6 peptides), E. canis, and A. phagocytophilum. KeyScreen is a fecal PCR test that detects 20 individual parasite species. If detected, Toxocara spp. will be further speciated (T. cati, T. canis, and T. leonina ...